5.1.1 Vediamo inspection tools Diagnostic software 5.1.1 vediamo Repair interface Equipment Program vci diagnostic pour voiture
5.1.1 Vediamo inspection tools Diagnostic software 5.1.1 vediamo Repair interface Equipment Program vci diagnostic pour voiture
Stripe is known for its strong security measures. It uses encryption, tokenization
FREE SHIPPING WORLDWIDE
We will try to deliver the product to you as soon as possible, just give us 1 or 2 weeks
Dear customer
Follow the store for more discounts ♥
Our store sells a large number of car and motorcycle repair and modification products.
Welcome to click on our store to find more products you want.
If you have any other questions after reading the detailed information page, please feel free to consult our customer service.
We will answer your questions as soon as you see the information!
1.The most important thing is: you must turn off the computer's anti-virus software and computer firewall before installation, otherwise you will not be able to open any files!
2.Before installing the software, please watch the installation video, our tutorial is very clear and can help you very well.
Detailed Description:
Vediamo - the distributed diagnostic application for engines (Verteilte Diagnose Anwendung for Motoren) - is a software system for electronic control unit (ECU) diagnostics which is integrated in the CAESAR/DIOGENES process chain. It allows diagnostics on any ECU over K-line as well as CAN, and encompasses all established protocols from RTMD+, MBISO, KWFB, KW2000 to UDS. Despite its name, Vediamo is no longer limited only to engine ECUs.
Vediamo is based on the Mercedes-Benz DCDI standard communication platform CAESAR and hence supports all communication hardware such as, e.g., Part C, Part A, Part Y, etc. DIOGENES data, used by all diagnostics applications in the company and which can be drawn from the central TAMINO data base, can be used as diagnostics data.
Future versions of Vediamo will be set up on the MVCI (ASAM standard) developed by GSP/ODE and will also support the ODX diagnostics data format.
The implemented client server architecture allows, among other things:
distributed diagnostics with multiple, simultaneous special client applications, e.g., test run control over PSR adapter while simultaneously verifying with Ecoute.
Expansion of the system by addition clients, Diagnostics, coding, or flashing of multiple ECUs simultaneously.
Product Introduction:
Name of software:Vediamo 5.01.01
Supported language: English, German
OS: Win7, Windows XP Professional
Software memory size : about 466MB
The Vediamo system configuration is used to configure an ECU system. With the Vediamo system configuration, it is possible to:
a.Generate system descriptions (VSB files)
b,Filter out measurements, functions, actuators, etc., which may not be used in the engine test facility.
c,Filter out errors and error environment data which result due to a missing complete vehicle system.
Application Areas:
The system configuration is used to adapt the available ECUs to the user's specific requirements, e.g., by selecting the standard connector, integration of automatically executed initialization services, selection of selected services from a longer list, and much more.
The architecture of the system allows it to be expanded easily by additional functionalities and even complete applications. This is done primarily using Java programs, for which Vediamo possesses a simple yet comprehensive connection, encompassing all ECU functions.
Communication hardware Hardware components (CAESAR, DCDI), which are connected between the PC and the ECU. The computer needs CAESAR software (CAESAR-slave library c32s.dll) to operate this hardware, and possibly hardware drivers.
ECU Electronic Control Unit. Electronic unit in vehicle which controls the function of the engine or other systems and which can communicate for diagnostic purposes with external equipment (tester, PC with communication hardware) either directly or by way of another ECU (gateway).
Operating Instructions :
After Vediamo has been installed (which of course requires Admin privileges), it can be run without Admin privileges. Since Vediamo accesses numerous files during operation and also writes in parts of these, certain access privileges may have to be granted.
The Vediamo files are installed into the ALLUSERSPROFILE folder. This folder is defined in environment variables and depends on the version of the operation system.
Important:
Stopping the server can take up to 20 seconds. If you start a Vediamo client before the server is completely ended, this can lead to unstable program results such as crashes and unrecognized hardware, or similar. In this case, use the task manager to make sure the process DiagServer is ended (or terminate it yourself), remove any possible "leftovers" from Ecoute or other clients and then start the client anew. It is not necessary to restart the computer.
Association with Hardware and Other Software:
1.work with CAESAR
The connection to the diagnostic hardware (CAESAR, DCDI) by the appropriate drivers and libraries forms the base of the Vediamo diagnostic server.
CAESAR hardware and software suppliers can be found here.
Part A: PCMCIA card, also requires Part B as well as drivers
Part C: ISA or PCI plug-in card with a variable number of piggy backs (processors for parallel diagnostics) and integrated multiplexer
Part E: OBD connector cable with integrated multiplexer, is connected to Part A+B, Y, or similar
Part F: Connector box for lab set up, can be used in place of Part E but does not have a multiplexer
Part P - eCom: also known as MVCI-Device, PDUAPI
Part X: Diagnostic part with wireless PC connector
Part Y: Diagnostic part with USB or serial PC connector
(Important: The Caesar Hardware: Part A / Part B / Part C / Part Y are not supported in Windows 7. )
2.work with LUCA
Langner Universal Communication API (LUCA) from Langner Communications AG in Hamburg. Provides a standardized programming interface for different communication protocols and allows effective protocol enhancements without intervention in the program flow. The communication between PSR and PSR adapter occurs over serial lines (3964R protocol) or over LAN (HDLC, TCP/IP) using the LUCA.DLL. The library LUCA.DLL is delivered together with Vediamo and can be installed (with a PSR adapter) when required.
Data sheet
- Origin
- Mainland China
- Certification
- CE
- Hign-concerned Chemical
- none
No customer reviews for the moment.